Residential Gas Water Heaters
GAS-FIRED (Applicable on some models) GAS-FIRED The ProMax® Power-Vent 40 and 50-gallon residential gas water heaters are equipped with Equipped with 110/120 volt electrical system, rating 3 amps or less 6-foot cord with standard 3-prong male connector ... Get Doc
Lennox EL296V Gas Furnace - HVAC Systems
On extremely cold days, the gas furnace takes over to maintain maximum comfort. Depending on outdoor conditions, you could realize measurable energy savings by pairing your EL296V with a heat pump. designed to be energy efficient and comfort wise ... Read Document
Service Facts Gas Furnace ? Induced Draft ? Two Stage Heat
Ampacity (In Amps) Max. Breaker Size (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) Service Facts Gas Furnace ? Induced Draft ? Two Stage Heat Author: tyafs Created Date: 12/21/2010 10:49:44 AM ... Content Retrieval
RV Converters & Amp Draw By: Mark J. Polk
RV Converters & Amp Draw By: Mark J. Polk Fluorescent Light 1-2 Amps Furnace 10-12 Amps LP Gas Leak Detector 1 Amp Overhead lights (Per Bulb) 1 Amp Porch Light 1 Amp Power Roof Vent 1.5 Amps Radio/Stereo 4 Amps Range Hood (Fan ... Retrieve Content
Piezo Ignition - Wikipedia, The Free Encyclopedia
Piezo ignition is a type of ignition that is used in portable camping stoves, gas grills and some lighters, and potato guns. Piezo ignition uses the principle of piezoelectricity, which in short, is the electric charge that accumulates in some materials in response to high pressure. It consists ... Read Article
Trane Submittal Upflow/Horizontal Gas Furnace - Single Stage ...
Upflow / Horizontal Gas Furnace - Single Stage High Efficiency Motor XT80 TUD1C080A9H41B CFM VS. TEMPERATURE RISE CFM (CUBIC FEET PER MINUTE) F.L. Amps FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) NATURAL GAS MODELS — Central heat- ... Content Retrieval
OMfort Et™-CoMpatiBle Wo-S AriaBle gaS furnaCe
• Furnace control board with self-diagnostics and provisions Max. Overcurrent Device (amps)4 15 15 15 Ship Weight (lbs) • Propane gas installations will have a high-stage rise approximately 4°F lower than shown in the tables. ... Access Content
Arc furnace At 42000 Amps - YouTube
Pacific Steel arc furnace melting scrapsteel, averaging 42,000 Ampères at 300 - 400 Volts ac. ... View Video
How To Check Oven Ignitor Amp Draw - YouTube
The ignitor must draw 3.5 amps or better in order for the safety valve to open and allow for ignition. How To Check Oven Ignitor Amp Draw Dan Webster. Subscribe Subscribed Unsubscribe 1,127 1K. Loading Gas Stove Oven Not Working or Heating - How to Troubleshoot Igniter ... View Video
TECHNICAL MANUAL - Alpine Air Hvac
NOMINAL WIDTH FOR GAS FURNACE A: Fits 14" Furnace Cabinet B: Fits 17 1/2" Furnace Cabinet C: Fits 21" Furnace Cabinet (1.25 x Circulator Blower Amps) + I.D. Blower Amps. 16 GMVC95 MODEL GMVC950453BX* GMVC950704CX* GMVC950905CX* GMVC950905DX* GMVC951155DX* ... Retrieve Doc
UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS-FIRED FURNACE
TWO-STAGE, VARIABLE SPEED GAS-FIRED FURNACE PUB. NO. 12-1095-09 Freedom 80vs MODELS AUD2B060A9V3VB AUD2B080A9V3VB AUD2C080A9V4VB AUD2C080B9V4VA Overcurrent Protection (Amps) PIPE CONN. SIZE (In.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs.) ... Access Content
Product Data - Dms.hvacpartners.com
Condensing Gas Furnace Series 1 Product Data A11263 The 59SC2 Multipoise Comfort Series Condensing Gas Furnace features energy efficiency of 92.1% AFUE gas efficiency and Motor Full Load Amps 4.6 6.8 4.6 7.9 7.4 7.9 6.5 11.1 11.1 RPM Range 500 - 1150 ... Retrieve Doc
GAS-FIRED MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED ...
DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. GMD1-60 GMD1-80 HEAT INPUT RATE (BTUH) GAS FURNACE MODEL NOMENCLATURE EXAMPLE MODEL GM D 1 - 6 0 N Furnace Motor Current Draw (Amps) vs. External Static pressure (in. WC.) Speed Tap \\ ... View Doc
Gas Heating Products - Trane.com
Gas Duct Furnace Model GLND/GLPD The Trane high efficiency indoor gas duct furnaces can achieve annual fuel Motor Amps 1.9 1.9 2.6 2.6 2.6 4.2 4.7 4.7 5.8 5.8 5.8 9.4 11.6 11.6. 7 UH-TS-1 A Complete Line of Gas Heating Products Indirect Fired ... Get Document
Venting A Water Heater - About.com Home
Venting a water heater properly requires a thorough understanding of the different types of venting that are available. The following is a list standard gas water heaters and the venting they use. ... Read Article
22-1797-03 Product Data - American Cooling And Heating
©2008 Trane Pub. No. 22-1797-03 Product Data 4YCY4024A through 4YCY4060A Single Packaged Convertible Gas/Electric 14 SEER 2 - 5 Ton, 40 - 120 KBTU R-410A ... Fetch Doc
Furnaces - Johnson Air Products
Furnaces 80% Gas Furnaces Downflow Full Load / Lock Rotor Amps 2.2 / 4.1 4.0 / 6.8 4.0 / 6.8 6.0 / 13.2 CP1014339 90+ 2-STAGE GAS FURNACE BLOWER (JAKEL) $274.75 CP1014529 COMFORTMAKER COMBUSTION BLOW ER 80+ (A & B-SERIES) JAKEL $156.26 ... View Doc
Fossil Fuel Heating Equipment - Fluke Corporation
Fluke Corporation Fossil fuel heating equipment-principles and troubleshooting techniques Fuel oil (diesel) furnaces are similar to gas furnaces except ... Read More
CMF Series Oil And Gas Downflow Furnaces - The Home Depot
TECHNICAL SPECIFICATIONS CMF Series Oil and Gas Furnace The CMF Series Furnace is a classic and time honored design. The CMF is a versatile and reliable product ... Get Document
GMSS92 / GCSS92 - Goodman® Manufacturing
GMSS92 / GCSS92 Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000–120,000 BTU/h Contents Overcurrent Device (amps)⁵ 15 15 15 15 15 15 15 15 Shipping Weight (lbs) 109 112 115 137 138 139 140 152 ¹ Natural Gas BTU/h ... Access Document
No comments: